CPX8216 and CPX8216T Installation and Use (6806800A52C)
Chapter 6 Chassis Operations
46
Note The voltage on the rating label adjacent to the power receptacle must agree with the type
of line or cord and the applied voltage.
4. Flip the rocker switch in the rear of the chassis to | (ON).
Recommended Power-Off Procedure
To shut down your CPX8216 chassis, follow these steps.
1. Shut down all software operations and the operating system. For dual-configured chassis, both
domains must be shut down.
2. Flip the rocker switch in the rear of the chassis to O (OFF).
This removes input power for all the power supplies. In dual-configured chassis, both domains
will lose input power.
Emergency Power-Off Procedure
!
Caution
Caution
Performing this step results in a loss of data and may cause damage to chassis
components in a running chassis. Use the following step only when normal shutdown
procedures cannot be followed.
This step applies to both AC and DC chassis.
In the event of an emergency, flip the rocker switch in the rear of the chassis to O (OFF). This
removes input power from the power supplies and will result in an abnormal shutdown of the
chassis.
Controls and Indicators
This section describes the various locations and functions of the controls and indicators of the
CPX8216 chassis. The controls and indicators for the various CompactPCI modules available
for the platform are not covered in this section, refer to Chapter 3, Platform Description for this
information.