Psion Mobile Devices Developers Guide
Chapter 13: Scanners
EAN 8 Settings
Imager
Scanner setting key = Barcode\EAN13\Imager
Note 1: Omnii only.
Note 2: All Psion computers except Omnii.
13.6.6 EAN 8 Settings
All Scanner Types
Scanner setting key = Barcode\C128\Scs
Non-decoded Laser Scanner
Scanner setting key = Barcode\EAN8
Scanner Setting Name Minimum Maximum Default GUI Name
Enabled 0 = off 1 = on 1 Enabled
Addendum
2
0 2 0 Addendum
2 Digit Addendum
1
0 = off 1 = on 0 Not available in the Scanners applet
5 Digit Addendum
1
0 = off 1 = on 0 Not available in the Scanners applet
Addendum Required
1
0 = off 1 = on 0 Not available in the Scanners applet
Scanner Setting Name Minimum Maximum Default GUI Name
Prefix Char 0 0xFFFF 0 Prefix Char
Suffix Char 0 0xFFFF 0 Suffix Char
Strip Leading 0 127 0 Strip Leading
Strip Trailing 0 127 0 Strip Trailing
Scanner Setting Name Minimum Maximum Default Values GUI Name
Enabled 0 = off 1 = on 1 Enabled
Include Chk 0 = off 1 = on 1 Include Check
Addendum 0 2 0 0 = Disabled
1 = Optional
2 = Required
Addendum
Transmit Code ID Character 0 = off 1 = on 0 Transmit Code ID Char