Chapter 3. Using the Monitor/Debug Firmware 3-31
Commands
RM Register Modify
Usage: RM reg data
The RM command modifies the contents of the register reg to data. The value for reg is the name
of the register, and the value for data may be a symbol name, or it is converted according to the
user-defined radix, normally hexadecimal.
dBUG preserves the registers by storing a copy of the register set in a buffer. The RM command
updates the copy of the register in the buffer. The actual value will not be written to the register
until target code is executed.
Examples:
To change program counter to contain the value 0x003f_8000, the command is:
rm pc 3f8000