Motorola 2.1 Guia de Instalação Página 726

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 952
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 725
14 - 8 WiNG CLI Reference Guide
14.1.6 flow
firewall-policy
Defines the session flow timeout for different packet types
Supported in the following platforms:
RFS7000
RFS6000
RFS4000
AP71xx
AP650
AP6511
AP6532
Syntax
flow [dhcp|timeout]
flow dhcp stateful
flow timeout [icmp|other|tcp|udp]
flow timeout [icmp|other|udp] <1-32400>
flow timeout tcp [close-wait|reset|setup|stateless-fin-or-reset|
stateless-general] <1-32400>
flow timeout tcp established <15-32400>
Parameters
[dhcp|timeout] Defines session flow timeout
dhcp stateful – Sets the DHCP flow between 1 and 32400 seconds
timeout [icmp|other|udp] <1-32400> – Sets the flow timeout based on
the packet type
icmp – Sets the timeout for ICMP packets between 1 and 32400
other – Sets the timeout for any packet type between 1 and 32400
seconds
udp <1-32400 – Sets the timeout for UDP packets between 1 and
32400 seconds
<1-32400> – Based on the packet type, the timeout is set
between 1 and 32400 seconds
tcp[close-wait|established|reset|setup|stateless-fin-or-reset
|stateless-general] – Based on the TCP state, the timeout is set
between 1 and 32400 seconds
close-wait <1-32400> – Closed TCP flow
established <15-32400> – Established TCP flow. Set the
timeout between 15 and 32400 seconds
reset <1-32400> – Reset TCP flow
setup <1-32400> – Opening TCP flow
stateless-fin-or-reset <1-32400> – Stateless TCP flow created
with FIN or RESET packet
stateless-general <1-32400> – Stateless TCP Flow
<1-32400> – Based on the packet type, the timeout is set
between 1 and 32400 seconds
Vista de página 725
1 2 ... 721 722 723 724 725 726 727 728 729 730 731 ... 951 952

Comentários a estes Manuais

Sem comentários