Motorola AT Commands G24-L Informações Técnicas Página 378

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 680
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 377
Modem Configuration and Profile
3-290 AT Commands Reference Manual August 5, 2008
?, Return the Value of the Last Updated S-register
This command displays the most recently updated value stored in an S-register.
Example
AT?
000
OK
AT?
003
OK
ATS36=5
OK
AT?
005
OK
&F, Set to Factory Defined Configuration
This command restores the factory default configuration profile. The G24 only supports one
factory default profile, 0.
The following table shows the &F parameters.
Command Type Syntax Response/Action Remarks
Read
AT? 000
OK
The Read command returns the value
of the last updated S-register.
Command Type Syntax Response/Action Remarks
Set
AT&F<value> OK
or:
+CMS ERROR: <err>
Read
AT&F? <current profile
number>
Test The Test command for &F is not
defined by ITU, and therefore is not
supported by the G24. The G24 returns
an error.
Table 3-190: &F Parameters
<Parameter> Description
<value> 0 Factory default configuration profile. This is the only value supported.
Vista de página 377
1 2 ... 373 374 375 376 377 378 379 380 381 382 383 ... 679 680

Comentários a estes Manuais

Sem comentários