2 Overview
AT&T SLW2500 Installation and Operation Manual
Housing
The SLW2500 optical node is furnished in an aluminum housing that protects the electronics
from weather and dissipates internally generated heat.
Figure 2-1 illustrates the SLW2500 housing and provides its dimensions:
Figure 2-1
SLW2500 housing dimensions — front and side view
12.25
21.60 10.99
34 OUT
6
3
7 8
2
1
4
5
Coaxial cable connections to the housing are made using conventional 5/8 inch
× 24 threads per
inch, stinger-type connectors. For strand mounting, the optional bracket must be used. If the
node is configured for strand mounting, the bracket is installed on the node at the factory. The
bracket provides two clamps, located 16 and 7/8 inches apart, that secure the strand with
5/16
× 20 stainless steel bolts.
Mounting Holes
Two threaded holes are located on the horizontal center-line on the rear of the housing. These
5/16”
× 18” × ¾” holes are separated by eleven inches center-to-center and can be used for
pedestal or surface mounting.