AT&T SLW2500 Installation and Operation Manual
Power Supply Settings
You can power the SLW2500 from 60 Vac or 90 Vac system supplies. The unit is shipped from
the factory set for 60 Vac (
LO). If your system uses 90 Vac powering, reposition the suitcase
jumper on the dc power supply to the 90 Vac (
HI) position to optimize the supply turn-on voltage
for the higher input range. Note that no damage results if the jumper is not changed. In a 90 Vac
system, changing the jumper ensures that the dc supply does not turn on until the proper input
voltage level is reached. This prevents excessive loading of the cable plant power supply during
turn-on after a power-off situation.
Figure 3-5 illustrates the location of the
LO/HI jumper:
Figure 3-5
SLW2500 power supply
SG2-PS
CAUTION
NO USER SERVICEABLE PARTS INSIDE
ASSEMBLED IN MEXICO
SEE INSTALLATION MANUAL FOR SERVICE
VOLTAGES I N EXCESS OF
300 VOLTS AR E PRESENT
UNDER COVER AND MAY
BE PR ESENT AFTER POWER
IS REMOVED
LO HI
24V 5V
ADJ
TEST
POINT
TEST
POINT
The dc supply can deliver 4.3 A at
+24 V and 0.850 A at +5 V. Test points are provided for 24 Vdc
and 5 Vdc supplies. Two green LEDs on the power supply indicate the overall health of the nodes
dc power bus. The power supply is factory calibrated for 24 V and should not need output voltage
adjustment; however, R51 is available if required. Figure 3-5 illustrates the location of R51
(
ADJ).
The ac input from the feederline to the power supply must be between 44 Vrms and 90 Vrms
with a line frequency of 50 Hz or 60 Hz. The waveshape of the input voltage must be
quasi-squarewave. The power supply features a self-protection attribute that shuts it down for
instantaneous line voltages higher than 200 V. A precision output regulator protects against
overcurrent and short circuits, thus providing a precise output voltage.