Página 1 - Product Reference Guide

P460/P360 MemoryScannersProduct Reference Guide

Página 2

viiiP460/P360 Memory Scanners Product Reference GuideIndexFeedback

Página 3 - P460/P360 Memory Scanners

5-30P460/P360 Memory Scanners Product Reference GuideEnable/Disable EAN-13*ENABLE EAN-13DISABLE EAN-13

Página 4

5-31Parameter MenusEnable/Disable Bookland EANScan the appropriate bar code below to enable or disable Bookland EAN.ENABLE BOOKLAND EAN *DISABLE BOOKL

Página 5 - Contents

5-32P460/P360 Memory Scanners Product Reference GuideDecode UPC/EAN SupplementalsSupplementals are characters (either 2 or 5) that are added on accord

Página 6 - Chapter 3. Operation

5-33Parameter MenusDecode UPC/EAN Supplemental RedundancyWith Autodiscriminate UPC/EAN Supplementals selected, this option adjusts the number of times

Página 7 - Chapter 5. Parameter Menus

5-34P460/P360 Memory Scanners Product Reference GuideTransmit UPC-A/UPC-E/UPC-E1 Check DigitScan the appropriate bar code below to transmit the symbol

Página 8

5-35Parameter MenusUPC-A PreambleThree options are given for lead-in characters for UPC-A symbols transmitted to the host device: transmit system char

Página 9

5-36P460/P360 Memory Scanners Product Reference GuideUPC-E PreambleThree options are given for lead-in characters for UPC-E symbols transmitted to the

Página 10 - Feedback

5-37Parameter MenusUPC-E1 PreambleThree options are given for lead-in characters for UPC-E1 symbols transmitted to the host device: Transmit system ch

Página 11 - About This Manual

5-38P460/P360 Memory Scanners Product Reference GuideConvert UPC-E to UPC-AThis parameter converts UPC-E (zero suppressed) decoded data to UPC-A forma

Página 12 - Service Information

5-39Parameter MenusConvert UPC-E1 to UPC-AThis parameter converts UPC-E1 decoded data to UPC-A format before transmission. After conversion, data foll

Página 13 - Symbol Support Center

ixAbout This ManualIntroductionThe P460/P360 Memory Scanners Product Reference Guide provides general instructions for setup, operation, troubleshooti

Página 14

5-40P460/P360 Memory Scanners Product Reference GuideEAN Zero ExtendIf this parameter is enabled, five leading zeros are added to decoded EAN-8 symbol

Página 15 - Business Partner for service

5-41Parameter MenusUPC/EAN Coupon CodeWhen this parameter is enabled, the Phaser decodes UPC-A, UPC-A with 2 supplemental characters, UPC-A with 5 sup

Página 16

5-42P460/P360 Memory Scanners Product Reference GuideEnable/Disable Code 128Scan the appropriate bar code below to enable or disable Code 128.*ENABLE

Página 17 - The Phaser Series Scanner

5-43Parameter MenusEnable/Disable UCC/EAN-128Scan the appropriate bar code below to enable or disable UCC/EAN-128. (See Appendix A, Bar Code Informati

Página 18 - The Cradle

5-44P460/P360 Memory Scanners Product Reference GuideLengths for Code 128No length setting is required for Code 128. The default setting is Any Length

Página 19 - Quick Startup Instructions

5-45Parameter MenusEnable/Disable ISBT 128 To enable or disable ISBT 128, scan the appropriate bar code below.*Enable ISBT 128Disable ISBT 128

Página 20

5-46P460/P360 Memory Scanners Product Reference GuideEnable/Disable Code 39Scan the appropriate bar code below to enable or disable Code 39.*ENABLE CO

Página 21 - Chapter 2

5-47Parameter MenusEnable/Disable Trioptic Code 39Trioptic Code 39 symbols always contain six characters. Trioptic Code 39 and Code 39 Full ASCII cann

Página 22 - Phaser handle

5-48P460/P360 Memory Scanners Product Reference GuideSet Lengths for Code 39Lengths for Code 39 may be set for any length, one or two discrete lengths

Página 23

5-49Parameter MenusSet Lengths for Code 39 (Continued)Length Within Range - This option allows you to decode a code type within a specified range. For

Página 24 - Scanner Power Options

xP460/P360 Memory Scanners Product Reference GuideNotational ConventionsThe following conventions are used in this document:• Italics are used to high

Página 25 - Charging the Battery

5-50P460/P360 Memory Scanners Product Reference GuideCode 39 Check Digit VerificationWhen enabled, this parameter checks the integrity of a Code 39 sy

Página 26 - Charge Status LED Indications

5-51Parameter MenusTransmit Code 39 Check DigitScan the appropriate bar code below to transmit the data with or without the check digit.TRANSMIT CODE

Página 27 - Changing the Battery

5-52P460/P360 Memory Scanners Product Reference GuideEnable/Disable Code 39 Full ASCIIScan the appropriate bar code below to enable or disable Code 39

Página 28 - Connecting to a Host

5-53Parameter MenusConvert Code 39 to Code 32Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32.Note:Code 39 must

Página 29 - IMPORTANT

5-54P460/P360 Memory Scanners Product Reference GuideCode 32 PrefixScan the appropriate bar code below to enable or disable the prefix character “A” t

Página 30

5-55Parameter MenusEnable/Disable Code 93Scan the appropriate bar code below to enable or disable Code 93.ENABLE CODE 93*DISABLE CODE 93

Página 31

5-56P460/P360 Memory Scanners Product Reference GuideSet Lengths for Code 93Lengths for Code 93 may be set for any length, one or two discrete lengths

Página 32

5-57Parameter MenusSet Lengths for Code 93 (Continued)Length Within Range - This option allows you to decode a code type within a specified range. For

Página 33 - Operation

5-58P460/P360 Memory Scanners Product Reference GuideEnable/Disable Interleaved 2 of 5Scan the appropriate bar code below to enable or disable Interle

Página 34 - Batch / Inventory Application

5-59Parameter MenusSet Lengths for Interleaved 2 of 5 Lengths for I 2 of 5 may be set for any length, one or two discrete lengths, or lengths within a

Página 35 - Alpha Data Entry

xiAbout This GuideNote:Symbol Technologies is not responsible for any damages incurred during shipment if the approved shipping container is not used.

Página 36 - _____________

5-60P460/P360 Memory Scanners Product Reference GuideSet Lengths for Interleaved 2 of 5 (Continued)Length Within Range - This option allows you to dec

Página 37 - <BK>=No

5-61Parameter MenusI 2 of 5 Check Digit VerificationWhen enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with

Página 38

5-62P460/P360 Memory Scanners Product Reference GuideTransmit I 2 of 5 Check DigitScan the appropriate bar code below to transmit the data with or wit

Página 39 - Scan and Transmit Application

5-63Parameter MenusConvert I 2 of 5 to EAN-13This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. In

Página 40 - System Menu

5-64P460/P360 Memory Scanners Product Reference GuideEnable/Disable Discrete 2 of 5Scan the appropriate bar code below to enable or disable Discrete 2

Página 41 - System Setup

5-65Parameter MenusSet Lengths for Discrete 2 of 5 Lengths for D 2 of 5 may be set for any length, one or two discrete lengths, or lengths within a sp

Página 42

5-66P460/P360 Memory Scanners Product Reference GuideSet Lengths for Discrete 2 of 5 (Continued)Length Within Range - This option allows you to decode

Página 43

5-67Parameter MenusEnable/Disable CodabarScan the appropriate bar code below to enable or disable Codabar.ENABLE CODABAR*DISABLE CODABAR

Página 44

5-68P460/P360 Memory Scanners Product Reference GuideSet Lengths for CodabarLengths for Codabar may be set for any length, one or two discrete lengths

Página 45

5-69Parameter MenusSet Lengths for Codabar (Continued)Length Within Range - This option allows you to decode a code type within a specified range. For

Página 46 - System Status

xiiP460/P360 Memory Scanners Product Reference GuideFinland/SuomiOy Symbol TechnologiesKaupintie 8 A 6FIN-00440 Helsinki, FinlandTel: 9 5407 580 (Insi

Página 47 - Erase File

5-70P460/P360 Memory Scanners Product Reference GuideCLSI EditingIf enabled, this parameter strips the start and stop characters and inserts a space a

Página 48 - Return to App

5-71Parameter MenusNOTIS EditingIf enabled, this parameter strips the start and stop characters from a decoded Codabar symbol.ENABLE NOTIS EDITING*DIS

Página 49 - Reset Default Application

5-72P460/P360 Memory Scanners Product Reference GuideEnable/Disable MSI PlesseyScan the appropriate bar code below to enable or disable MSI Plessey.EN

Página 50 - Suffix Values

5-73Parameter MenusSet Lengths for MSI Plessey Lengths for MSI Plessey may be set for any length, one or two discrete lengths, or lengths within a spe

Página 51

5-74P460/P360 Memory Scanners Product Reference GuideSet Lengths for MSI Plessey (Continued)Length Within Range - This option allows you to decode a c

Página 52 - ADF Rules

5-75Parameter MenusMSI Plessey Check DigitsThese check digits at the end of the bar code verify the integrity of the data. At least one check digit is

Página 53

5-76P460/P360 Memory Scanners Product Reference GuideTransmit MSI Plessey Check DigitScan the appropriate bar code below to transmit the data with or

Página 54 - Scanning

5-77Parameter MenusMSI Plessey Check Digit AlgorithmWhen the two MSI Plessey check digits option is selected, an additional verification is required t

Página 55 - Hold at an Angle

5-78P460/P360 Memory Scanners Product Reference GuideSecurity OptionsLinear Code Type Security LevelsThe Phaser offers four levels of decode security

Página 56 - Test Symbols

5-79Parameter MenusLinear Security Level 3Code types other than the following must be successfully read twice before being decoded. The following code

Página 57

xiiiAbout This GuideIf you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for service.For the latest vers

Página 58 - Keypad Operation

5-80P460/P360 Memory Scanners Product Reference GuideBi-directional RedundancyThis parameter is only valid when a Linear Code Type Security Level (see

Página 59

5-81Parameter MenusUPC/EAN Security LevelThe Phaser offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are pro

Página 60

5-82P460/P360 Memory Scanners Product Reference GuideUPC/EAN SECURITY LEVEL 2UPC/EAN Security Level 3If you have tried Security Level 2, and are still

Página 61 - Chapter 4

5-83Parameter MenusRS-232 ParametersBaud RateBaud rate is the number of bits of data transmitted per second. The scanner's baud rate setting shou

Página 62 - Troubleshooting

5-84P460/P360 Memory Scanners Product Reference GuideBAUD RATE 4800*BAUD RATE 9600BAUD RATE 19200BAUD RATE 38400

Página 63

5-85Parameter MenusParityA parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device

Página 64

5-86P460/P360 Memory Scanners Product Reference GuideSelect SPACE parity and the parity bit is always 0.SPACEIf no parity is required, select NONE.*NO

Página 65 - Optional Accessories

5-87Parameter MenusHardware HandshakingThe data interface consists of an RS-232 port. The port has been designed to operate either with or without the

Página 66 - Technical Specifications

5-88P460/P360 Memory Scanners Product Reference GuideScan the bar code below if no Hardware Handshaking is desired.*NONEScan the bar code below to sel

Página 67 - Pin-outs

5-89Parameter MenusWhen Option 2 is selected, RTS is always high or low (user-programmed logic level). However, the scanner waits for CTS to be assert

Página 68 - Table 4-4. Scanner Pin-outs

xivP460/P360 Memory Scanners Product Reference Guide

Página 69 - Beeper Indications

5-90P460/P360 Memory Scanners Product Reference GuideACK/NAKWhen this option is selected, after transmitting data, the cradle expects either an ACK, A

Página 70

5-91Parameter MenusACK/NAK with ENQThis combines the two previous options.ACK/NAK with ENQXON/XOFFAn XOFF, Transmit Off, character turns the scanner t

Página 71 - Chapter 5

5-92P460/P360 Memory Scanners Product Reference GuideHost Serial Response Time-outThis parameter specifies how long the scanner waits for an ACK, NAK

Página 72 - Table 5-1. Default Table

5-93Parameter MenusStop Bit SelectThe stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares

Página 73

5-94P460/P360 Memory Scanners Product Reference GuideBeep on <BEL>When this parameter is enabled, the scanner beeps when a <BEL> character

Página 74

5-95Parameter MenusMCL-Net ParametersMCL-Net Baud RateBaud rate is the number of bits of data transmitted per second. Scan the appropriate bar code be

Página 75

5-96P460/P360 Memory Scanners Product Reference GuideBAUD RATE 4800BAUD RATE 9600BAUD RATE 19200*BAUD RATE 38400

Página 76

5-97Parameter MenusMCL-Net Hex Addressing ModeScan the appropriate bar code below to set the MCL-Net Hex addressing mode. The default mode is Disabled

Página 77 - Set Default Parameter

5-98P460/P360 Memory Scanners Product Reference GuideScanner AddressScan the following barcode, followed by 3 digits from the numeric barcode section

Página 78 - Communication Protocol

5-99Parameter MenusNumeric Bar CodesFor parameters requiring specific numeric values, scan the appropriately numbered bar code(s).01234

Página 79 - Batch/Inventory Application

1-1Chapter 1 The Phaser Series ScannerIntroductionThe P460/P360 Memory Scanners bring new flexibility and economy to data capture and data management

Página 80 - Host Type

5-100P460/P360 Memory Scanners Product Reference GuideNumeric Bar Codes (Continued)56789

Página 81

5-101Parameter MenusNumeric Bar Codes (Continued)CancelIf you make an error, or wish to change your selection, scan the bar code below.CANCEL

Página 82

5-102P460/P360 Memory Scanners Product Reference Guide

Página 83 - Sleep Time

A-1Appendix ABar Code InformationUCC/EAN-128UCC/EAN-128 is a convention for printing data fields with standard Code 128 bar code symbols. UCC/EAN-128

Página 84 - Date Separator

A-2P460/P360 Memory Scanners Product Reference GuideTable A-1. Reading Standard Code128 & UCC/EAN 128Standard Code 128UCC/EAN-128 Effect and Examp

Página 85 - Hour Type

A-3Bar Code InformationAIM Code IdentifiersEach AIM Code Identifier contains the three-character string ]cm where:] = Flag Character (ASCII 93)c = Cod

Página 86 - Decimal Separator

A-4P460/P360 Memory Scanners Product Reference GuideThe modifier character is the sum of the applicable option values based on the following table.Tab

Página 87 - Date Format

A-5Bar Code InformationCodabar 0 No check digit processing.1 Reader has checked check digit.3 Reader has stripped check digit before transmission.Exam

Página 88 - Key Click

A-6P460/P360 Memory Scanners Product Reference GuideAccording to AIM standards, a UPC with supplemental bar code is transmitted in one of the followin

Página 89 - Laser On Time

A-7Bar Code InformationTable A-5. ASCII Character Set ASCIIValueFull ASCII Code 39 Encode Char.Keystroke ASCIIValueFull ASCII Code 39 Encode CharKeys

Página 90 - Host Override

1-2P460/P360 Memory Scanners Product Reference GuideThe CradleThe PL 460 and PL 360 Cradles act as a:•stand• communication interface with the host• ba

Página 91 - Beeper Options

A-8P460/P360 Memory Scanners Product Reference GuideASCIIValueFull ASCII Code 39 Encode Char.Keystroke ASCIIValueFull ASCII Code 39 Encode CharKeystro

Página 92 - Beeper Volume

A-9Bar Code InformationASCIIValueFull ASCII Code 39 Encode Char.Keystroke ASCIIValueFull ASCII Code 39 Encode CharKeystroke1098 +B b 1113 +Q q1099 +C

Página 93 - Power Detect Beep

A-10P460/P360 Memory Scanners Product Reference GuideALT Keys Keystroke ALT Keys Keystroke ALT Keys Keystroke2064 ALT 2 2075 ALT K 2086 ALT V2065 ALT

Página 94 - Beep After Good Decode

A-11Bar Code InformationPF Keys Keystroke PF Keys Keystroke PF Keys Keystroke4001 PF 1 4009 PF 9 4017 PF 174002 PF 2 4010 PF 10 4018 PF 184003 PF 3 40

Página 95 - Decode Options

A-12P460/P360 Memory Scanners Product Reference GuideNumericKeypadKeystroke NumericKeypadKeystroke NumericKeypadKeystroke6042 * 6049 1 6056 86043 + 60

Página 96 - Enable/Disable UPC-E

B-1Appendix BAutomatic Project DownloadThe Phaser P470/P370 RF scanner is shipped from the factory with a pre-installed default application. This ful

Página 97 - Enable/Disable UPC-A

B-2P470/370 RF Scanner Product Reference GuideNote that designer always appends the .prj suffix to the directories it creates to store project files.T

Página 98 - Enable/Disable UPC-E1

C-1Appendix CMessages and Error CodesIntroductionThis chapter contains information on messages displayed on the scanner.MessagesThe scanner displays

Página 99 - Enable/Disable EAN-8

C-2P460/P360 Memory Scanners Product Reference Guide

Página 100 - Enable/Disable EAN-13

Index-1Numerics123Scan . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17Aaccessories . . . . . . . . . . . . . . . . . . . . . . . . . 4-5ADF

Página 101 - Enable/Disable Bookland EAN

1-3The Phaser Series ScannerQuick Startup InstructionsBelow is an index of Quick Startup Instructions to help get you up and going quickly. These inst

Página 102 - Decode UPC/EAN Supplementals

Index-2P460/P360 Memory Scanners Product Reference Guideenable/disable . . . . . . . . . . . . . . 5-72set lengths . . . . . . . . . . . . . 5-73,

Página 103 - DECODE UPC/EAN

Index-3IndexDDaisy-Chaining Cradles . . . . . . . . 2-4, 3-6, 4-7datatransmitting to host . . . . . . . . . . . . . . . 3-6data formatting . . .

Página 104 - UPC-E, or UPC-E1 check digit

Index-4P460/P360 Memory Scanners Product Reference Guidequantity entry . . . . . . . . . . . . . . . . . . . 3-4reviewing/deleting batch records

Página 105 - UPC-A Preamble

Index-5IndexSsample symbols . . . . . . . . . . . . . . . . . . . . 3-24Scan and Transmit Applicationcommunication protocol . 3-2, 3-9, 5-2, 5-8manua

Página 106 - UPC-E Preamble

Index-6P460/P360 Memory Scanners Product Reference GuideUPC-A Preamble . . . . . . . . . . . . . . . . . . . . 5-3UPC-E . . . . . . . . . . . . . .

Página 107 - UPC-E1 Preamble

Thank you for your input—We value your comments.Tell Us What You Think...We’d like to know what you think about this Manual. Please take a moment to f

Página 110 - EAN Zero Extend

2Symbol Technologies, Inc. One Symbol Plaza, Holtsville N.Y. 11742-130070-37690-04Revision A — December 2003Quick Startup InstructionsBelow is an inde

Página 112 - Enable/Disable Code 128

1-4P460/P360 Memory Scanners Product Reference GuideCommonly Used P460/P360 Programming Bar CodeBelow are commonly used programming bar codes. You can

Página 113 - Enable/Disable UCC/EAN-128

2-1Chapter 2 Set UpIntroductionThis chapter covers the procedures for setting up the Phaser and its accessories.Unpacking Remove the scanner from its

Página 114 - Lengths for Code 128

2-2 P460/P360 Memory Scanners Product Reference GuideCablesConnecting the Cable to the Scanner1. Power down all devices that will be connected to the

Página 115 - Enable/Disable ISBT 128

2-3Set Up3. Turn the cable twist-lock 1/8 turn clockwise to seat it.Figure 2-2. Locking the Cable to the Phaser4. Gently pull the cable to make certa

Página 116 - Enable/Disable Code 39

2-4 P460/P360 Memory Scanners Product Reference GuideSetting Up the Cradle On the bottom of the cradle are three ports. COM1 connects to the host comp

Página 117 - *DISABLE TRIOPTIC CODE 39

2-5Set UpCharging the BatteryBefore its first use, the scanner battery may need to be charged. It can be charged:• Using the cradle• Using a cable• Us

Página 118 - Set Lengths for Code 39

2-6 P460/P360 Memory Scanners Product Reference GuideThe cradle recharges batteries in the scanner only when the scanner is in the cradle. A scanner w

Página 119 - CODE 39 - ANY LENGTH

2-7Set UpChanging the BatteryOnce a battery is fully charged, it will generally last up to 12 hours without being returned to the cradle. By returning

Página 120 - *DISABLE CODE 39 CHECK DIGIT

2-8 P460/P360 Memory Scanners Product Reference GuideInserting the Battery1. Place the top portion of the battery (curved side up, contacts toward top

Página 121 - Transmit Code 39 Check Digit

2-9Set UpUsing A Synapse Cable with the cradle1. Make sure all host devices are powered down.IMPORTANTBefore power is provided to the cradle (step 6),

Página 122 - *DISABLE CODE 39 FULL ASCII

P460/P360 Memory ScannersProduct Reference Guide70-37690-04Revision ADecember 2003

Página 123 - Convert Code 39 to Code 32

2-10 P460/P360 Memory Scanners Product Reference GuideUsing A Synapse Cable with the Scanner1. Make sure all host devices are powered down.IMPORTANTBe

Página 124 - Code 32 Prefix

2-11Set UpWand Emulation, OCIA, OCR, Keyboard WedgesSee the instructions packed with the appropriate Synapse cable. An adapter cable is required. See

Página 125 - Enable/Disable Code 93

2-12 P460/P360 Memory Scanners Product Reference Guide

Página 126 - Set Lengths for Code 93

3-1Chapter 3 OperationIntroductionThis chapter covers how to use the Phaser scanner.Default ApplicationsThe Memory Phaser is shipped from the factory

Página 127 - CODE 93 - ANY LENGTH

3-2P460/P360 Memory Scanners Product Reference GuideInitial PowerupAfter a few seconds, the System Banner is replaced by the system initialization scr

Página 128 - DISABLE INTERLEAVED 2 OF 5

3-3OperationNumeric Data EntryThe default application also allows you to manually enter data if no bar code is present. By default, this feature is en

Página 129

3-4P460/P360 Memory Scanners Product Reference GuideEliminating Repetitive ScanningTo eliminate repetitive scanning of identical items, you can enter

Página 130 - I 2 of 5 - ANY LENGTH

3-5OperationReviewing and Deleting Stored RecordsWhile running the Batch/Inventory application, you can review and delete stored data. Press the <F

Página 131 - OPCC CHECK DIGIT

3-6P460/P360 Memory Scanners Product Reference GuideTransmitting Batch/Stored Data to the HostWhen you are ready to transmit your stored (Batch) data

Página 132 - Transmit I 2 of 5 Check Digit

3-7OperationOptional - To establish which scanner the data originated from, and to prevent a buffer over-write, the scanner ID of daisy-chained scanne

Página 133 - Convert I 2 of 5 to EAN-13

ii 2001-2003 by Symbol Technologies, Inc. All rights reserved.No part of this publication may be reproduced or used in any form, or by any electrical

Página 134 - *DISABLE DISCRETE 2 OF 5

3-8P460/P360 Memory Scanners Product Reference GuideSystem MenuThe system menu allows the user to set up the operation of the scanner, such as loading

Página 135

3-9OperationSystem SetupSystem Setup allows you to configure the scanner’s basic settings such as date and time. Option Description0. Set Com Protocol

Página 136 - D 2 of 5 - ANY LENGTH

3-10P460/P360 Memory Scanners Product Reference GuideNote:The scanner contains a backup power source to retain the time and date information for up to

Página 137 - Enable/Disable Codabar

3-11OperationApp. ControlApp. Control allows you to control your application, specifically, load new system application files on your scanner, reset y

Página 138 - Set Lengths for Codabar

3-12P460/P360 Memory Scanners Product Reference Guide1. Set Default App Reinstalls the default application and returns all parameters to their factory

Página 139 - CODABAR - ANY LENGTH

3-13Operation2. System Code Updates the scanner operating system (Firmware). An RS-232 cable is required. It connects the scanner (not the cradle) to

Página 140 - CLSI Editing

3-14P460/P360 Memory Scanners Product Reference GuideParameter ControlParameter Control allows you to control the scanner parameters such as Scan Para

Página 141 - NOTIS Editing

3-15OperationErase FileErase File Erase File allows you to erase your scanner batch data. It is recommended that data files be transferred from the sc

Página 142 - Enable/Disable MSI Plessey

3-16P460/P360 Memory Scanners Product Reference GuideVersionReturn to AppVersion This option displays the version of firmware (operating system) run

Página 143 - Set Lengths for MSI Plessey

3-17Operation123Scan123Scan is an intuitive Windows based utility that allows you to customize your scanner setup and generate Advanced Data Formattin

Página 144 - *MSI PLESSEY - ANY LENGTH

iiiContentsAbout This ManualIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 145 - MSI Plessey Check Digits

3-18P460/P360 Memory Scanners Product Reference GuideSuffix Values123Scan generated programming bar codes for two commonly used suffixes (Enter and Ta

Página 146 - (DISABLE)

3-19Operation5/96/97/98/99/9RESET SCANNER

Página 147 - *MOD 10/MOD 10

3-20P460/P360 Memory Scanners Product Reference GuideTo append a Tab* to the transmitted bar code data, scan all nine (9) ADF rule bar codes and then

Página 148 - Security Options

3-21Operation6/97/98/99/9RESET SCANNER

Página 149 - Linear Security Level 4

3-22P460/P360 Memory Scanners Product Reference GuideScanningThe scanner ships with the default application and default parameters that is ready-to-us

Página 150 - Bi-directional Redundancy

3-23OperationRight WrongHold at an AngleDo not hold the scanner directly over the bar code. Laser light reflecting directly back into the scanner from

Página 151 - UPC/EAN Security Level

3-24P460/P360 Memory Scanners Product Reference GuideTest SymbolsTo ensure your scanner is working properly, try scanning the following bar codes. If

Página 152 - UPC/EAN Security Level 3

3-25OperationP460/P360 1D Scanner Decode ZoneFigure 3-3. P460/P360 1D Scanner Decode Zone0 in.0 cm 5 in.12.7 cm 10 in.25.4 cm 15 in.38.1 cm 20 i

Página 153 - RS-232 Parameters

3-26P460/P360 Memory Scanners Product Reference GuideKeypad OperationInstead of scanning a bar code, you can enter the bar code data using the keypad

Página 154 - BAUD RATE 38400

3-27Operationtransferred to the host yet. A high-pitched beep lets you know that the entry has been transferred to the host. To return to numeric mode

Página 155

ivP460/P360 Memory Scanners Product Reference GuideRemoving the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 156 - Check Receive Errors

3-28P460/P360 Memory Scanners Product Reference Guide

Página 157 - Hardware Handshaking

4-1Chapter 4 Maintenance And SpecificationsIntroductionThis chapter explains how to maintain your scanner and the specifications for it.Maintenance•

Página 158 - RTS/CTS OPTION 1

4-2 P460/P360 Memory Scanners Product Reference GuideTroubleshootingRefer to Appendix C, Messages and Error Codes for additional troubleshooting infor

Página 159 - Software Handshaking

4-3Maintenance And SpecificationsScanned data is incorrectly displayed on the host.Scanner is not programmed to work with the host.Ensure the proper h

Página 160

4-4 P460/P360 Memory Scanners Product Reference GuideThe scanner does not scan the programming bar codes in this guide.Bar code symbol is unreadable.C

Página 161 - XON/XOFF

4-5Maintenance And SpecificationsNote:If after performing these checks the symbol still does not scan, contact your distributor or call the Symbol Sup

Página 162 - RTS Line State

4-6 P460/P360 Memory Scanners Product Reference GuideTechnical SpecificationsTable 4-2. Technical Specifications for P460/P360 1D ScannerItem Descript

Página 163 - ASCII Format

4-7Maintenance And SpecificationsPin-outsCradleThe following table shows the pin-outs for both COM1 and COM2 on the cradle.Table 4-3. Cradle Pin-outsP

Página 164 - Intercharacter Delay

4-8 P460/P360 Memory Scanners Product Reference GuideScannerThe following table shows the pin-outs for the scanner.Table 4-4. Scanner Pin-outsPin Scan

Página 165 - MCL-Net Parameters

4-9Maintenance And SpecificationsBeeper IndicationsTable 4-5. Beeper Indications Beeper Sequence IndicationStandard UseShort high tone A bar code symb

Página 166 - *BAUD RATE 38400

vContentsTroubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 167 - MCL-Net Hex Addressing Mode

4-10 P460/P360 Memory Scanners Product Reference Guide

Página 168 - Scanner Address

5-1Chapter 5 Parameter MenusIntroductionThis chapter has the optional parameter bar codes necessary to program the Phaser memory scanner.Operational

Página 169 - Numeric Bar Codes

5-2P460/P360 Memory Scanners Product Reference GuideThe following table lists the defaults for all parameters. If you wish to change any option, scan

Página 170 - Numeric Bar Codes (Continued)

5-3Parameter MenusUPC/EANUPC-E Enable 5-26UPC-A Enable 5-27UPC-E1 Disable 5-28EAN-8 Enable 5-29EAN-13 Enable 5-30Bookland EAN Disable 5-31Decode UPC/E

Página 171

5-4P460/P360 Memory Scanners Product Reference GuideUCC/EAN-128 Enable 5-43ISBT-128 Enable 5-45Code 39Code 39 Enable 5-46Trioptic Code 39 Disable 5-47

Página 172

5-5Parameter MenusDiscrete 2 of 5 Disable 5-64Set Length(s) for D 2 of 5 12 5-65CodabarCodabar Disable 5-67Set Lengths for Codabar 5-55 5-69CLSI Editi

Página 173 - Bar Code Information

5-6P460/P360 Memory Scanners Product Reference GuideRS-232RS-232 Host Type Standard 5-10Baud Rate 9600 5-84Parity None 5-85Check Receive Errors Disabl

Página 174

5-7Parameter MenusSet Default ParameterScanning this bar code returns all parameters to the values listed in Table 5-1 (factory settings), but does no

Página 175 - AIM Code Identifiers

5-8P460/P360 Memory Scanners Product Reference GuideCommunication ProtocolThe bar codes below set the communication protocol used by the default appli

Página 176 - ]C1AimId

5-9Parameter MenusBatch/Inventory ApplicationThis communication protocol is used when you are ready to transmit your batch records (data collected whe

Página 177

viP460/P360 Memory Scanners Product Reference GuideUPC-E Preamble. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 178

5-10P460/P360 Memory Scanners Product Reference GuideHost TypeRS-232 Host TypesMost RS-232 hosts work fine with the default settings, however, three R

Página 179

5-11Parameter MenusScan the appropriate bar code below to select an RS-232 Host Interface.*STANDARD RS-232ICL RS-232NIXDORF RS-232 Mode ANIXDORF RS-23

Página 180

5-12P460/P360 Memory Scanners Product Reference GuideCode ID Characters for RS-232 Host TypesSelecting the ICL, Fujitsu, or Nixdorf RS-232 host interf

Página 181

5-13Parameter MenusSleep TimeScan the bar code below to select how long the scanner will “stay awake” (not power down) in seconds after a trigger pull

Página 182

5-14P460/P360 Memory Scanners Product Reference GuideDate SeparatorScan the appropriate bar code below to select which separator to use when displayin

Página 183

5-15Parameter MenusHour TypeScan the appropriate bar code below to select how to display the hour and transmit it to the host device. Choose 12 HOUR (

Página 184

5-16P460/P360 Memory Scanners Product Reference GuideDecimal SeparatorScan the appropriate bar code below to select what separator to display when you

Página 185 - Automatic Project Download

5-17Parameter MenusDate FormatScan the appropriate bar code below to select how to format the date when it is displayed and transmitted to the host de

Página 186

5-18P460/P360 Memory Scanners Product Reference GuideKey ClickScan the appropriate bar code below to select whether the keypad click is enabled or not

Página 187 - Messages and Error Codes

5-19Parameter MenusLaser On TimeThis parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 seco

Página 188

viiContentsUPC/EAN Security Level 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-81UPC/EAN Security

Página 189 - Numerics

5-20P460/P360 Memory Scanners Product Reference GuideHost OverrideThis parameter allows the scanner to communicate when it is not on any auxiliary pow

Página 190

5-21Parameter MenusBeeper OptionsBeeper ToneScan the appropriate bar code below to select a decode beep frequency (tone). Choose LOW FREQUENCY, MEDIUM

Página 191

5-22P460/P360 Memory Scanners Product Reference GuideBeeper VolumeScan the appropriate bar code below to select a beeper volume. Choose LOW VOLUME, ME

Página 192

5-23Parameter MenusPower Detect BeepScan the appropriate barcode below to enable or disable the Power Detection Beep.POWER DETECT BEEP DISABLED*POWER

Página 193

5-24P460/P360 Memory Scanners Product Reference GuideBeep After Good DecodeScan the appropriate bar code below to select whether or not the scanner be

Página 194

5-25Parameter MenusDecode OptionsTransmit “No Read” MessageScan the appropriate bar code below to select whether or not a “No Read” message is transmi

Página 195 - Tell Us What You Think

5-26P460/P360 Memory Scanners Product Reference GuideEnable/Disable UPC-EScan the appropriate bar code below to enable or disable UPC-E.*ENABLE UPC-ED

Página 196

5-27Parameter MenusEnable/Disable UPC-AScan the appropriate bar code below to enable or disable UPC-A.*ENABLE UPC-ADISABLE UPC-A

Página 197

5-28P460/P360 Memory Scanners Product Reference GuideEnable/Disable UPC-E1Scan the appropriate bar code below to enable or disable UPC-E1.ENABLE UPC-E

Página 198

5-29Parameter MenusEnable/Disable EAN-8Scan the appropriate bar code below to enable or disable EAN-8 or EAN-13.*ENABLE EAN-8DISABLE EAN-8

Comentários a estes Manuais