2-14 Overview
SG4000 Installation and Operation Manual
You can distinguish the SG4000 1 GHz port entry assemblies by the addition of a terminal
clamp block on the bottom of the port entry board. The terminal clamp secures the AC wiring
that connects each of the port entry assemblies. The 870 MHz port entry assemblies have the
AC wiring soldered directly to the board. The terminal clamp design on the 1 GHz model
enables field personnel to replace the port entry board if necessary.
Figure 2-10 illustrates a bottom view of the port entry board and the AC terminal clamp.
Figure 2-10
Port entry board – AC terminal clamp
Terminal clamp
Ensure that you remove all power to the node before attempting to service the port entry board.