4-4 Modules
SG4000 Installation and Operation Manual
Figure 4-2 illustrates the SG4-R/* receiver with the cover installed (left) and the cover
removed (right).
Figure 4-2
SG4-R/* cover on, cover off
1V/mW
OPTICAL
INPUT
OPTICAL
RECEIVER
RF
TP
ENABLE
FAULT
1 GHz
1550
1310
SLOPE
FAULT
ON
FAULT
Wavelength
selection jumper
Optical power
test point
LEDs
LME
RF test point
JXP attenuator
Table 4-1 provides additional information on the user-related features of the SG4-R/*.
Table 4-1
SG4-R/* features
Feature Description
Wavelength selection jumper
Used with 1310 nm or 1550 nm transmitters, the wavelength selection
jumper on top of the SG4-R/* optimizes the optical power test point and
optical power status indicator calibration for the system wavelength. Note
that the jumper has no effect on the optical-to-RF performance (gain,
flatness, and slope) of the module.
Optical power test point
Enables monitoring of the optical power level at the input to the module.
The nominal scale factor is 1.0 V/mW.
Receiver JXP attenuator
JXP style interstage pad that enables you to make forward path gain
adjustments.
RF output test point
-20 dB test point that enables you to measure carriers throughout the
forward band.
Receiver enable
A green LED (
ON) that provides visual indication of the receiver’s enable
status.
Fault indicator
A red LED that illuminates when the module is disabled.
Linear Mid-stage Equalizer
Passive plug-in board that helps develop the overall station slope and
affects all of the RF modules attached to the receiver. You can access the
LME by removing the receiver chassis cover.