3-4 Bench Setup and Operation
SG4000 Installation and Operation Manual
You can configure the SG4000 forward path with up to four SG4-R receivers and up to two
forward configuration plug-in boards. Each board has a specific function and receiver
combination associated with it and is clearly labeled. The forward configuration board, in
location 1, services the SG4-R receivers in optics slots 1 and 2, as illustrated in Figure 3-2. The
forward configuration board in location 4 services the SG4-R receivers in lid optics slots 7 and 8.
For detailed information on the SG4-R receiver, see Section 4, “Modules.”
Table 3-1 lists the SG4000 forward-path configuration options.
Table 3-1
SG4000 forward-path configuration options
Option Forward Path Configuration
X
Forward split, one receiver
A
Redundant split, two receivers
B
Segmented, two receivers
C
Segmented, redundant, four receivers
D
Segmented, four receivers