3-16 Bench Setup and Operation
SG4000 Installation and Operation Manual
Figure 3-15 illustrates the forward redundant segmented 2X board. Jumper J5 is shown in the
normal default position that enables signal flow to each output connector. When configuring for
a single output, move
J5 to the left position, thereby terminating output connector J6 (OUT 2).
Figure 3-15
Forward redundant segmented 2X board
OUT 1
J5
SEC RX PRI RX
OUT 2
TERM NORM
Figure 3-16 illustrates the forward redundant segmented 2X signal flow. Loss is measured at
870 MHz.
Figure 3-16
Forward redundant segmented 2X – signal flow
Loss = 8.7 dB
J5
-4.5 dB
-4.0 dB
Out 2
Out 1
-0.5 dB
Rx Pri
Rx Sec
To set up the forward redundant segmented 2X option:
1 Confirm that SG4-R/* receivers are installed in lid optics slots 1, 2, 7, and 8.
2 Confirm that two forward redundant segmented 2X boards are installed in the forward
configuration board locations 1 and 4, as illustrated in Figure 3-14.
3 Install an RF cable from the SG4-R/* in lid optics slot 1 to the primary input of the forward
redundant segmented 2X board in configuration location 1.
4 Install an RF cable from the SG4-R/* in lid optics slot 2 to the secondary input of the same
configuration board.
5 Install an RF cable from the SG4-R/* in lid optics slot 7 to the primary input of the forward
redundant segmented 2X board in configuration location 4.
6 Install an RF cable from the SG4-R/* in lid optics slot 8 to the secondary input of the same
configuration board.
The RF cables should be approximately five inches long and have black boots on the
connector signifying forward path.
7 Connect the appropriate forward RF cables from the RF modules to each forward redundant
segmented 2X board.