Motorola SG4-DRT-2X Instruções de Operação Página 56

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 108
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 55
3-28 Bench Setup and Operation
SG4000 Installation and Operation Manual
Figure 3-25 illustrates the combined redundant return plug-in board required for combined
redundant return configuration. Jumpers
J3, J6, and J9 are shown in the normal default
position. Jumper
J9 enables/disables the signal flow to output connector J10 (TX2). Jumper J9 is
shown in the lower position to enable the output connector path to TX2. The RF output to TX1 is
connected to a return transmitter in lid optics slot 4. The RF output to TX2 is connected to a
return transmitter in lid optics slot 3.
Figure 3-25
Combined redundant return board
J1
J2
T5
J3
J6
J9
C15
C13
C11
SM
J12
IN2
J4
IN4
J7
IN3
J8
TX1
J11
TX2
J10
IN1
J5
L2
L1
R21
R15
R14 R13
R12
R9R10
C10
C9
C7
C6
C3
T3
T4
T2
T1
Figure 3-26 illustrates the signal flow through the combined redundant return board.:
Figure 3-26
Combined redundant return – signal flow
Loss = 0.9 dB
J3
J9
J6
-0.5 dB
-3.5 dB
+11 dB
+11 dB
-3.5 dB
-3.5 dB
-3.5 dB
Tx2
Tx1
SM
In1
In3 In4
In2
To set up the combined redundant return option:
1 Confirm that transmitters are installed in lid optics slots 3 and 4.
2 Confirm that a combined redundant return board is installed in the return configuration
board location 2, as illustrated in Figure 3-24.
3 Position J9 in the lower position to enable the output to TX2.
4 Connect an RF cable from each of the combined redundant return board outputs to both
transmitter inputs.
The RF cable should be approximately five inches long and have red boots on the connector