4-16 Modules
SG4000 Installation and Operation Manual
The EPIM contains microprocessor circuitry that collects telemetry data from all modules
installed in the SG4000 modular node. When a transponder module is installed, the EPIM
serves as the primary interface to the transponder, relaying the data to a remote interface.
The EPIM board contains a 3-gang, dual-in-line-package (DIP) switch, six jumper-selectable
header switches, indicator LEDs, and a reset switch. Table 4-9 provides descriptions and
functions of these user-interface settings.
Table 4-9
EPIM board user-interface settings
Description Function
Switch S2
Controls the attenuation of the ingress control switches (ICS) when they are installed in
the return paths of the RF modules. The three-position switch is factory preset for
minimum attenuation; however, they can be switched to a –6 dB state, and for a
maximum attenuation of approximately 40 dB. The following list indicates the dip
switch and its corresponding housing port:
S2-1
RF port 1
S2-2 RF port 2
S2-3 RF port 3
S2-4 RF
port 4
S2-5 RF
port 5
S2-6
RF port 6
Note: S2-7 and S2-8 are unused.
Switch SW1 Auto
The receiver pair in lid optics slots 1 and 2 operates in a redundant mode. The default
receiver is in lid optics slot 1. Upon loss of optical input power (below –5 dBm) on the
primary receiver, the EPIM automatically switches operation to the secondary receiver
in lid optics slot 2.
Switch SW1 A
The redundant operation is overridden and the receiver in lid optics slot 1 is enabled
regardless of optical input power.
Switch SW1 B
The redundant operation is overridden and the receiver in lid optics slot 2 is enabled
regardless of optical input power.
Switch SW2 Auto
The receiver pair in lid optics slots 7 and 8 operates in a redundant mode. The default
receiver is in lid optics slot 7. Upon loss of optical input power (below –5 dBm) on the
primary receiver, the EPIM automatically switches operation to the secondary receiver
in lid optics slot 8.
Switch SW2 A
The redundant operation is overridden and the receiver in lid optics slot 7 is enabled
regardless of optical input power.
Switch SW2 B
The redundant operation is overridden and the receiver in lid optics slot 8 is enabled
regardless of optical input power.
Status LED D6
This LED blinks constantly to provide visual indication of a properly functioning EPIM
module.
ICS LED D5
This LED is on when one or more ICS switches are in the –6 dB or –40 dB state.
Reset switch
You must press the reset switch after you make any changes to the station
configuration, including changing configuration plug-ins or adding or removing
modules.
The EPIM and SIC cable must be installed:
in all redundant receiver configurations
when ICS operation is used
when a status monitor transponder is installed