4-12 Modules
SG4000 Installation and Operation Manual
Feature Description
Return Input JXP Attenuator
JXP style attenuator pad that enables you to make return path level
adjustments.
Ingress Control Switch (ICS)
Optional, active plug-in device that enables you to attenuate the return
path of the individual RF module in 0, -6 dB, and off states. It is
controlled through the optional EPIM or transponder module. You can
access the ICS by removing the RF module chassis cover.
FSB Board
In the event that the standard FSB is replaced, bench alignment of the new board is
recommended to ensure proper flatness is achieved. The controls on the FSB are illustrated in
Figure 4-8.
Figure 4-8
FSB board
C6
R2
C1
R3
C3
C4
R1
C2
Table 4-6 identifies and describes the controls on the FSB board.
Table 4-6
FSB board controls
Control Use
R1, R2, C1, C2
Adjusts the low end of the band.
R3, C3, C4
Adjusts the mid band.
C6
Adjusts the high end of the band.
Comentários a estes Manuais